21
Audio (not available)
Settings: ENABLED, DISABLED
Allows you to enable and disable the audio
capabilities of the AdderView CATx 1000
unit.
ADDERVIEW CATx 1000
Advanced Options
DDC Options
Power Control
USB Country Code
Enter-Select
F1-More menus
Esc-Quit
Firmware Version 1.01b06
Add Computers
Settings: AUTO, MANUAL
Each time the master switch within a KVM cascade is power cycled, it checks for
newly added computers. This option allows you to determine whether such new
computers are automatically added to the computer list or whether you would
prefer to update the list manually.
Advanced Options
Advanced options are available only to the Admin user and consist of settings
that are related to specialist areas such as power control and DDC.
DDC Options
The options within this section are related to the Display Data Channel features
supported by the AdderView CATx 1000. DDC is an industry standard format that
allows computer systems to be informed of the capabilities of the video monitor
connected to them.
DDC Source
Settings: AUTO, LOCAL, REMOTE, DEFAULT
Determines which user port monitor should be interrogated to discover its
capabilities. AUTO begins with the local user port and if it fails, it then checks
the remote port and if that also fails to produce a result, it uses a set of default
values. The LOCAL and REMOTE settings force the unit to interrogate only
the local and remote monitors respectively, and DEFAULT uses only the pre-
programmed settings.
To get here
1 From a local or remote keyboard, log on
as a standard (limited options) or admin
user.
2 Press
(hotkeys can change).
3 Press to select ‘More menus.
4 Press
again to select Advanced
menus’.
5 Select ‘Setup Options’.
DDC Refresh
Settings: AT START, DISABLED
AT START sets the AdderView CATx 1000 to read DDC information from the
selected source at power up. When DISABLED, no new DDC data is sought and
existing information is used. When viewing this menu, press F7 to discover
DDC information from the chosen source immediately.
Power Control
The options within this section are
concerned with the operation of the POWER
CONTROL port when used to command
optional system power control units.
Baud Rate
Settings: 1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200
Congures the communication speed of
the POWER CONTROL port and must match
the speed used by the connected power
switch(es). Note: The PSU-8MASTER and
PSU-8SLAVE power switches supplied by
Adder require a setting of 9600.
Format
Settings: NONE.8.1, ODD.8.1, EVEN.8.1, NONE.8.2, NONE.7.2, ODD.7.2, EVEN.7.2
Congures the data format used by the serial port and must match the format
used by the connected power switch(es). The NONE/ODD/EVEN portion relates
to the parity checking; the 7/8 value is the size of the data byte and the 1/2
value determines the stop bit(s) used after each data byte.
continued
ADDERVIEW CATx 1000
Power Control
Power Control ENABLED
Baud Rate
Format
9600
NONE.8.1
Space-Toggle
-Up -Down Esc-Quit